Sale!

CGA G-6.7

$47.50

Safe Handling of Liquid Carbon Dioxide Containers That Have Lost Pressure, Fourth Edition
standard by Compressed Gas Association, 12/23/2009

Category:

Description

This publication provides techniques and information that allow owners and operators of bulk carbon dioxide containers to safely repressurize containers that have decreased below their design operating temperatures (typically 200 psig -20 degrees F).

Carbon dioxide auto-refrigerates as gas is removed from a container. This causes the remaining liquid to decrease in temperature until it is colder than the container design limits. Special techniques and considerations need to be used to safely repressurize and warm the dry ice or cold liquid that remains inside a bulk container before returning it to normal service. These procedures are based upon CGA-sponsored testing and the best available technical knowledge.

Improper repressurization of bulk carbon dioxide containers could lead to catastrophic failure due to the extreme cold temperatures of the liquid/solid carbon dioxide making the container walls brittle.

Containers can lose pressure due to a number of upset conditions such as failure of a pressure building vaporizer, failure of a safety relief device to close, excessive liquid or vapor withdrawal.

The 4th edition includes new information on both ASME and EN pressure vessels. It is intended to be internationally harmonized to include typical European pressure vessel limitations and the recently revised ASME code ( 3.5 safety factor vs the older 4).

Product Details

Edition:
4th
Published:
12/23/2009
Number of Pages:
29
File Size:
1 file , 830 KB