Sale!

TO-22-A002 – Designing to Reduce Infection Transmission: Influence of Aerosolization Procedures on Near Zone Particle Number and Transport

$7.50

Conference Proceeding by ASHRAE, 2022

Category:

Description

Experiments were conducted in a controlled environment of a scaled test room. Nebulizer operated at 2L/min for one hour resulted in a spike of particle count for an hour after approximately three hours of release. Particle count highlighted the difference in two regions of the scaled test room where air flow was minimal. Impingers monitored concentration levels around the mannequin, lower region of the scaled room. Sustained increase was noted after three hours of release on the side the mannequin where the nebulizer was operated. Particle numbers returned to background levels after four hours.

Product Details

Published:
2022
Number of Pages:
4
Units of Measure:
Dual
File Size:
1 file , 1.5 MB
Product Code(s):
D-TO-22-A002
Note:
This product is unavailable in Russia, Belarus