Moisture Content of Indoor Air and Structures in Buildings with Vapor-Permeable Envelopes

$7.50

Conference Proceeding by ASHRAE, 2001

Category:

Description

It is known that a vapor-resistant layer on the inside of an insulated envelope in cold climates is needed to prevent excessive diffusion of water vapor from indoor air into the building envelope. However, the required magnitude of this vapor resistance has been debated in recent years. In this paper, the moisture transfer between indoor air and the building envelope and the moisture performance of a building envelope that has no plastic vapor retarder is analyzed with field measurements and numerical simulations. The results show that the diffusion resistance of the internal surface should be greater than the diffusion resistance of the external surface for a structure safe from moisture but that the vapor resistance of the vapor retarder can be significantly below that provided by polyethylene, even in cold climates. Meanwhile, the moisture transfer between indoor air and the building envelope can moderate the indoor humidity, which improves indoor climate and comfort.


Authors: Carey J. Simonson, Ph.D.; Mikael H. Salonvaara; Tuomo Ojanen

Citation: Thermal Performance of the Exterior Envelopes of Buildings VIII

Keywords: December, Florida, 2001

Citation: Thermal Performance of the Exterior Envelopes of Whole Buildings VIII

Product Details

Published:
2001
File Size:
1 file , 850 KB
Product Code(s):
D-7971