Description
A study was made of an automatic- and a manual-defrost refrigerator/freezer combination, andan upright and a chest freezer to measure the effect on energy consumption of five variableusage conditions: thermostat setting, ambient temperature, food load, door-opening frequency,and relative humidity. No evaluation was made of the effect of frost build-up.Ambient temperature and thermostat settings were found to have considerably greater effect onenergy consumption than door-opening and relative humidity changes for the specimens tested.
Product Details
- Published:
- 1977
- Number of Pages:
- 11
- File Size:
- 1 file , 780 KB
- Product Code(s):
- D-CH-77-13-3
- Note:
- This product is unavailable in Russia, Belarus